A wet-forming ceramic fiber board line can send substantial volumes of filtrate back to stock preparation and still need fresh water every shift. The return-flow meter measures what moves inside the system. Freshwater demand comes from what leaves it, including dryer evaporation, purge and cleaning discharge. A second ledger tracks the solids returned with the water, because those solids can change how the next batch forms and drains.

Draw the boundary before sizing the tank
Start at the freshwater inlet and follow the wet-forming circuit through stock preparation, the former, the filtrate tank and its return line. Include the dryer when calculating the circuit's net water demand. Water removed from the wet board there leaves the process. Mark the incoming water in purchased liquids or wet feed if those flows are material.
Shift accounting worksheet; numerical values are illustrative.
| Flow | Where to record it | What the reading answers |
|---|---|---|
| Freshwater makeup | Meter at the inlet to the wet-forming circuit | How much fresh water the circuit actually draws |
| Filtrate or white water | Return line from the collection tank to stock preparation | How much water recirculates during the same period |
| Moisture carried by boards | Weigh representative wet blanks and corresponding dried boards, with moisture measured on the agreed basis | How much water goes to the dryer and how much stays in the finished product |
| Purge, cleaning discharge and other losses | Record where each stream leaves the system | Which operating activities increase makeup demand |
| Tank inventory | Record opening and closing levels or volumes | Whether this shift drew down or filled the circuit |
Give the liquid-ring vacuum pump's seal-water circuit its own line on the utility schedule. Measure its makeup separately when it has an independent cooling and recirculation loop. This also lets maintenance investigate seal-water temperature without guessing from the white-water tank readings.
Reconcile one shift on a consistent basis
Suppose a sample shift sends 5.00 tonnes of wet blanks to drying at 50% moisture by wet mass. The blanks contain 2.50 tonnes of dry solids and 2.50 tonnes of water. For the illustration, the same boards leave the dryer with 0.05 tonnes of residual water and no measured dry-solids loss. The dryer has therefore removed 2.45 tonnes of water.
Shift accounting worksheet; numerical values are illustrative.
| Net water leaving the example boundary | Tonnes per shift |
|---|---|
| Water evaporated in drying | 2.45 |
| Water remaining in the dried boards | 0.05 |
| Deliberate purge | 0.45 |
| Cleaning discharge | 0.10 |
| Total freshwater makeup at steady inventory | 3.05 |
The figures illustrate the accounting method. The example assumes no other external water inputs, losses or change in inventory. Add any rise in stored water to the makeup requirement and subtract any fall. Use the same shift cutoff for the water meter, production weights and tank readings. A process flow through the return pipe can be counted separately for pump sizing.
Put each recovered stream on its own line
Wet edge trim and rejected wet blanks can go back to the pulper when their grade and condition are acceptable. White-water recovery yields a different stream. It can carry fine fiber, filler and binder from vacuum drainage. Its wet mass alone gives the operator little information about the dose entering the next batch.
Record the recovered mass, total solids concentration, source grade and destination batch. For example, 1,500 kg of return stock at 0.8% total solids contributes 12 kg of dry solids. A fiber credit requires a verified fiber fraction. Use a controlled blend trial to establish the effect on slurry consistency, forming cycle, wet blank moisture and the finished board properties specified for the order.
If drainage lengthens while the former's vacuum trace stays near its baseline, compare return-stock solids and water chemistry with the last stable shift. If the tank level falls with a steady feed, use the ledger to identify whether evaporation, a purge or a drain accounts for the change. A supplier and buyer can use the same sheet to agree on meter locations, the recovery streams to be handled and which tanks or pumps belong in the quoted package.
See the ceramic fiber board production line and the continuous board line engineering guide for the equipment context.
Frequently Asked Questions
Why does a recirculating board line still need fresh water?
Water leaves through dryer evaporation, residual board moisture, purge and cleaning discharge. Freshwater makeup replaces these net losses and any increase in stored water.
Can recovered stock be counted as recovered fiber?
Measure total solids first. Returned solids can include fiber, filler and binder, so a fiber credit requires a verified fiber fraction.
What does the 3.05 tonne example represent?
It is an illustrative shift water balance at steady inventory, with no other external water inputs or losses. It is not a consumption guarantee for a production line.